NRT Notification Detail
Outage and degradation of GRAS level 1 b data
|
DATE: 2013-01-29 11:41
TYPE: NRT-GTS
|
Description
|
Dear ROM SAF GTS User



Issued: 2013-01-29 11:45Z



Due to an outage and degradation of upstream GRAS level 1b data no ROM SAF products were disseminated between instrument sensing times 2013-01-29 06:24:07Z and 2013-01-29 07:18:49Z. Products are expected to be degraded until 13:45 Z and will be flagged accordingly.



Please see detailed message from EUMETSAT below.



Kind regards

The ROM SAF Team





Forwarded Message:

Subject:Data outage for GRAS on Metop-A today, 29 Jan 2012

From: Yago Andres

Date: 2013-01-29 11:13 UTC



Dear all,



due to a problem at the downlink station in Svalbard, the operational processing chain for Metop-A was interrupted for ~50min (06:24-07:18). The interruption has caused a reset in the operational POD.



The automatic POD reset occurred at a sensing time of 07:18 UTC, but unfortunately, it did not work as expected. A manual reset has thus been triggered for sensing time 2013-01-29 09:45:00.00. Data will be flagged as degraded up until ca. 13:45 UTC.



With kind regards,



Yago Andres





-------------------------------

Yago Andrés

POD Engineer

EUMETSAT

Eumetsat Alle 1

D-64295 Darmstadt

Tlf: +49 6151 807 665

Fax: +49 6151 807 304
|
Back to NRT Notifications ListNewer Older
|
|
|
|